Home / Products / Flat Cables





Fill the form below and we'll get back to you shortly.
Conductor: We use high precision methods to manufacture conductors made from high purity electrolytic grade, bright annealed, flexible bunched bare copper. These conductors comply with international standards such as IS 8130, BS 6360, IEC 228, and VDE 0295, ensuring consistent performance and reliability.
Insulation: Designed to endure challenging environments, the cables feature insulation made from Oil & Water Resistant EPR/EPDM/XLPO-based Elastomer Compound.
Sheath: The sheath, made from a special Elastomer Compound suitable for permanent immersion in drinking water, safeguards the internal components, ensures reliability and endurance, and helps maintain the electrical integrity of the cable.
| Core | Asian & African Markets | European Markets | New European Colour Code |
|---|---|---|---|
| 3 core | Red, Yellow, Blue | Black, Blue, Brown | Brown, Black, Grey |
| 4 core | Red, Yellow, Blue, Green | Black, Blue, Brown, Green | 4G: Brown, Black, Grey, Green/Yellow OR 4C: Brown, Black, Grey, Blue |
| Sheath | Blue | Blue | Blue |
![]() | ![]() | ||
![]() | ![]() |
Reference Standards: BS 6920, WRAS, KTW, W270, ACS, BS 6007, IEC 60245, CEI 20-19, VDE 0282, AS 3191, AS/NZS 5000.1, HD 22.1, NF C 32-201, and French Standard 32-102-16.
Working Voltage: 450/750 V, 600/1000 V, and 650/1100 V
Test Voltage: 2500 V
Temperature: -40°C to 90°C
Cable Nomenclature: TML-B, TML-B RD, S1BB-F, S07BB-F, TLT 07RN8-F, Drinking water cable, Drin Cable, Potable Water Cable, WRAS approved Clean Water Cable, KTW Approved Cable, ACS Approved Cable, Norme AD8 cable, S1BBH2-F, TML-B FLAT, S07BBH2-F, S1BNH2-F, A07VVH6-F, H07VVH6-F
| No. x Sq mm | Outer Dimensions mm x mm | Max. Resistance at 20°C ohm/km | Current Capacity at 40°C amps |
|---|---|---|---|
| 3 x 1.0 | 10.0 x 4.6 | 18.1 | 11 |
| 3 x 1.5 | 11.1 x 5 | 12.1 | 14 |
| 3 x 2.5 | 13 x 5.9 | 7.41 | 18 |
| 3 x 4.0 | 15.4 x 6.7 | 4.95 | 26 |
| 3 x 6.0 | 17.5 x 7.5 | 3.3 | 31 |
| 3 x 10 | 22.3 x 9.3 | 19.1 | 42 |
| 3 x 16 | 26.3 x 10.8 | 1.21 | 57 |
| 3 x 25 | 32.2 x 13.1 | 0.78 | 72 |
| 3 x 35 | 35.9 x 14.3 | 0.554 | 90 |
| 3 x 50 | 41.4 x 16.5 | 0.386 | 115 |
| 3 x 70 | 50.5 x 19.5 | 0.272 | 143 |
| 3 x 95 | 58.5 x 22.5 | 0.206 | 165 |
| No. x Sq mm | Outer Dimensions mm x mm | Max. Resistance at 20°C ohm/km | Current Capacity at 40°C amps |
|---|---|---|---|
| 4G x 1.0 | 12.6 x 4.6 | 18.1 | 11 |
| 4G x 1.5 | 14.2 x 5.0 | 12.1 | 14 |
| 4G x 2.5 | 16.5 x 6.0 | 7.41 | 18 |
| 4G x 4 | 19.7 x 6.7 | 4.95 | 26 |
| 4G x 6 | 22.7 x 7.7 | 3.3 | 31 |
| 4G x 10 | 28.6 x 9.4 | 19.1 | 42 |
| 4G x 16 | 34.3 x 11.0 | 1.21 | 57 |
| 4G x 25 | 4.2 x 13.2 | 0.78 | 72 |
| 4G x 35 | 47.4 x 14.7 | 0.54 | 90 |
| 4G x 50 | 55.0 x 16.8 | 0.386 | 115 |
| 4G x 70 | 65.7 x 20 | 0.272 | 143 |
| 4G x 95 | 76.4 x 23 | 0.206 | 165 |
Note: Insulation thickness, Sheath thickness and overall dimensions are nominal values. The number of wires is approximate and strand diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance as per IS 8130/1984, BS-6360, IEC-60228 & VDE-0295.


Conductor: We use high-quality, pure copper that's been carefully processed for flexibility and durability. It meets trusted international standards like IS 8130, BS 6360, IEC 228, and VDE 0295 — so you get performance you can count on.
Insulation: The inner layer is made with a specially designed PVC compound that resists water, oil, and grease. It helps protect the cable in tough conditions, ensuring long-lasting safety.
Sheath: On the outside, we use a strong yet flexible PVC layer that can handle rough use and resist wear and tear — giving your cable the strength it needs, wherever it's used.
| Core | Asian & African Markets | European Markets |
|---|---|---|
| 4 core | Red, Yellow, Blue, Green | Black, Blue, Brown, Green |
| Sheath | Blue | Blue |
![]() | ![]() |
Reference Standards: IS 694, BS 6500, IEC 60227, CEI 20-20, VDE 0281, SABS 1574, AS 3191, AS/NZS 5000.1, HD 21.1, NF C 32-201, and French Standard 32-102-16.
Working Voltage: 450/750 V, 600/1000 V, and 650/1100 V
Test Voltage: 3000 V
Temperature Range: -15°C to +70°C
Cable Nomenclature: H07VVH2-F, H07VVH6-F, S07VVH2-F, A07VVH2-F, S07VVH6-F, PVC FLAT CABLE, A07VVH6-F, H07VVH6-F
| No. x Sq mm | Outer Dimensions mm x mm | Max. Resistance at 20°C ohm/km | Current Capacity at 40°C amps |
|---|---|---|---|
| 4G x 1.0 | 15.0 x 4.6 | 18.1 | 11 |
| 4G x 1.5 | 16.4 x 5.0 | 12.1 | 14 |
| 4G x 2.5 | 19.4 x 6.0 | 7.41 | 18 |
| 4G x 4 | 22.7 x 6.7 | 4.95 | 26 |
| 4G x 6 | 25.6 x 7.7 | 3.3 | 31 |
| 4G x 10 | 32.2 x 9.4 | 19.1 | 42 |
| 4G x 16 | 37.7 x 10.8 | 1.21 | 57 |
| 4G x 25 | 46.0 x 13.1 | 0.78 | 72 |
| 4G x 35 | 51.0 x 14.4 | 0.554 | 90 |
Note: Insulation thickness, Sheath thickness and overall dimensions are nominal values. The number of wires is approximate and strand diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance as per IS 8130/1984, BS-6360, IEC-60228 & VDE-0295.


Conductor: Made from high-purity, flexible copper wires that are bright annealed and bunched together. These conductors meet international quality standards such as IS 8130, BS 6360, IEC 228, and VDE 0295.
Insulation: Uses a specially formulated PVC material that acts as a strong insulator. It resists water, oil, grease, and other harmful substances, ensuring safe and long-lasting performance.
Sheath: Covered with a tough yet flexible PVC outer layer that offers excellent protection against wear and tear, even in demanding environments.
| Core | Asian & African Markets | European Markets |
|---|---|---|
| 4 core | Red, Yellow, Blue, Green | Black, Blue, Brown, Green |
| Sheath | Blue | Blue |
Reference Standards: IS 694, BS 6500, IEC 60227, CEI 20-20, VDE 0281, SABS 1574, AS 3191, AS/NZS 5000.1, HD 21.1, NF C 32-201, and French Standard 32-102-16.
Working Voltage: 450/750 V, 600/1000 V, and 650/1100 V
Test Voltage: 3000 V
Temperature Range: -15°C to 70°C
| No. x Sq mm | Outer Dimensions mm x mm | Max. Resistance at 20°C ohm/km | Current Capacity at 40°C amps |
|---|---|---|---|
| 4G x 1.0 | 15.0 x 4.6 | 18.1 | 11 |
| 4G x 1.5 | 16.4 x 5.0 | 12.1 | 14 |
| 4G x 2.5 | 19.4 x 6.0 | 7.41 | 18 |
| 4G x 4 | 22.7 x 6.7 | 4.95 | 26 |
| 4G x 6 | 25.6 x 7.7 | 3.3 | 31 |
| 4G x 10 | 32.2 x 9.4 | 19.1 | 42 |
| 4G x 16 | 37.7 x 10.8 | 1.21 | 57 |
| 4G x 25 | 46.0 x 13.1 | 0.78 | 72 |
| 4G x 35 | 51.0 x 14.4 | 0.554 | 90 |
Note: Insulation thickness, Sheath thickness and overall dimensions are nominal values. The number of wires is approximate and strand diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance as per IS 8130/1984, BS-6360, IEC-60228 & VDE-0295.





Conductor: Manufactured using high-purity, electrolytic-grade, bright annealed, flexible bunched bare copper. Our conductors comply with internationally recognized standards including IS 8130, BS 6360, IEC 228, and VDE 0295. This ensures optimal conductivity and performance reliability.
Insulation: The cables are insulated with a high-quality elastomeric compound based on EPR, EPDM, or XLPO, offering excellent resistance to oil and water. This provides enhanced durability and safe operation in demanding environments.
Sheath: An outer sheath made from robust and flexible EPR, EPDM, or NBR-based elastomer compound offers superior mechanical protection while maintaining flexibility. This ensures long service life even under harsh working conditions.
| Core | Asian & African Markets | European Markets | New European Colour Code |
|---|---|---|---|
| 3 core | Red, Yellow, Blue | Black, Blue, Brown | Brown, Black, Grey |
| 4 core | Red, Yellow, Blue, Green | Black, Blue, Brown, Green | 4G: Brown, Black, Grey, Green/Yellow OR 4C: Brown, Black, Grey, Blue |
| Sheath | Choice of Black or Blue | Choice of Black or Blue | Choice of Black or Blue |
Reference Standards: BS 6007, IEC 60245, CEI 20-19, VDE 0282, AS 3191, AS/NZS 5000.1, HD 22.1, NF C 32-201, and French Standard 32-102-16.
Working Voltage: 450/750 V, 600/1000 V, and 650/1100 V
Test Voltage: 2500 V
Operating Temperature Range: -40°C to +90°C
Cable Nomenclature: S1BBH2-F, TML-B FLAT, S07BBH2-F, S1BNH2-F, AD8, A07VVH6-F, H07VVH6-F
| Name Type | Alternate Names / Variants |
|---|---|
| General / Functional | − RUBBER Flat Submersible Cable − Flat Pump Cable − Submersible Pump Cable |
| Application-Based | − Borewell Pump Cable − Underwater Pump Cable − Deep Well Pump Cable |
| Construction-Based | − 3 Core Flat Cable − Flat 3 Core Submersible Cable − Flat RUBBER Sheathed Cable |
| Material-Based | − Copper RUBBER Flat Cable − RUBBER Insulated & Sheathed Flat Cable |
| Regional / Market Terms | − Bore Pump Cable (Australia) − Drop Cable (North America) |
| No. x Sq mm | Outer Dimensions mm x mm | Max. Resistance at 20°C ohm/km | Current Capacity at 40°C amps |
|---|---|---|---|
| 3 x 1.0 | 10.0 x 4.6 | 18.1 | 11 |
| 3 x 1.5 | 11.1 x 5 | 12.1 | 14 |
| 3 x 2.5 | 13 x 5.9 | 7.41 | 18 |
| 3 x 4.0 | 15.4 x 6.7 | 4.95 | 26 |
| 3 x 6.0 | 17.5 x 7.5 | 3.3 | 31 |
| 3 x 10 | 22.3 x 9.3 | 19.1 | 42 |
| 3 x 16 | 26.3 x 10.8 | 1.21 | 57 |
| 3 x 25 | 32.2 x 13.1 | 0.78 | 72 |
| 3 x 35 | 35.9 x 14.3 | 0.554 | 90 |
| 3 x 50 | 41.4 x 16.5 | 0.386 | 115 |
| 3 x 70 | 50.5 x 19.5 | 0.272 | 143 |
| 3 x 95 | 58.5 x 22.5 | 0.206 | 165 |
| No. x Sq mm | Outer Dimensions mm x mm | Max. Resistance at 20°C ohm/km | Current Capacity at 40°C amps |
|---|---|---|---|
| 4G x 1.0 | 12.6 x 4.6 | 18.1 | 11 |
| 4G x 1.5 | 14.2 x 5.0 | 12.1 | 14 |
| 4G x 2.5 | 16.5 x 6.0 | 7.41 | 18 |
| 4G x 4 | 19.7 x 6.7 | 4.95 | 26 |
| 4G x 6 | 22.7 x 7.7 | 3.3 | 31 |
| 4G x 10 | 28.6 x 9.4 | 19.1 | 42 |
| 4G x 16 | 34.3 x 11.0 | 1.21 | 57 |
| 4G x 25 | 4.2 x 13.2 | 0.78 | 72 |
| 4G x 35 | 47.4 x 14.7 | 0.554 | 90 |
| 4G x 50 | 55.0 x 16.8 | 0.386 | 115 |
| 4G x 70 | 65.7 x 20 | 0.272 | 143 |
| 4G x 95 | 76.4 x 23 | 0.206 | 165 |
Note: Insulation thickness, Sheath thickness and overall dimensions are nominal values. The number of wires is approximate and strand diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance as per IS 8130/1984, BS-6360, IEC-60228 & VDE-0295.


Conductor: We manufacture our conductors in compliance with international standards, using high-purity electrolytic grade, bright annealed, flexible bunched bare copper. Adhering to IS 8130, BS 6360, IEC 228, and VDE 0295, they offer enhanced reliability and consistent performance.
Insulation: Our insulation is designed to perform in challenging conditions. Made from an oil and water-resistant EPR/EPDM/XLPO-based elastomer compound, it helps the cables stand out with dependable protection.
Sheath: When it comes to durability, our tough and flexible EPR/EPDM/NBR-based elastomer sheath ensures long-lasting performance without compromising flexibility.
| Core | Asian & African Markets | European Markets |
|---|---|---|
| 4 core | Red, Yellow, Blue, Green | Black, Blue, Brown, Green |
| Sheath | Choice of Black or Blue | |
![]() | ![]() |
Reference Standards: BS 6007, IEC 60245, CEI 20-19, VDE 0282, AS 3191, AS/NZS 5000.1, HD 22.1, NF C 32-201, and French Standard 32-102-16.
Working Voltage: 450/750 V, 600/1000 V, to 650/1100 V
Test Voltage: 2500 V
Temperature Range: -40°C to 90°C
Cable Nomenclature: S1BBH2-F, TML-B FLAT, S07BBH2-F, S1BNH2-F, AD8, A07VVH6-F, H07VVH6-F
| No. x Sq mm | Outer Dimensions mm x mm | Max. Resistance at 20°C ohm/km | Current Capacity at 40°C amps |
|---|---|---|---|
| 4G x 1.0 | 15.0 x 4.6 | 18.1 | 11 |
| 4G x 1.5 | 16.4 x 5.0 | 12.1 | 14 |
| 4G x 2.5 | 19.4 x 6.0 | 7.41 | 18 |
| 4G x 4 | 22.7 x 6.7 | 4.95 | 26 |
| 4G x 6 | 25.6 x 7.7 | 3.3 | 31 |
| 4G x 10 | 32.2 x 9.4 | 19.1 | 42 |
| 4G x 16 | 37.7 x 10.8 | 1.21 | 57 |
| 4G x 25 | 46.0 x 13.1 | 0.78 | 72 |
| 4G x 35 | 51.0 x 14.4 | 0.554 | 90 |
Note: Insulation thickness, Sheath thickness and overall dimensions are nominal values. The number of wires is approximate and strand diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance as per IS 8130/1984, BS-6360, IEC-60228 & VDE-0295.


Conductor: High-purity, bright annealed, flexible bunched bare copper, made as per IS 8130, BS 6360, IEC 228 & VDE 0295 for excellent conductivity and durability.
Insulation: Oil and water-resistant elastomer compound based on EPR, EPDM, or XLPO, offering strong protection in harsh conditions.
Sheath: Tough and flexible outer layer made from EPR, EPDM, or NBR elastomer, designed to resist abrasion, chemicals, and mechanical stress.
| Core | Asian & African Markets | European Markets |
|---|---|---|
| 4 core | Red, Yellow, Blue, Green | Black, Blue, Brown, Green |
| Sheath | Choice of Black or Blue | |
![]() | ![]() |
Reference Standards: BS 6007, IEC 60245, CEI 20-19, VDE 0282, AS 3191, AS/NZS 5000.1, HD 22.1, NF C 32-201, and French Standard 32-102-16.
Working Voltage: 450/750 V, 600/1000 V, and 650/1100 V
Test Voltage: 2500 V
Temperature: -40°C to 90°C
Cable Nomenclature: A07VVH6-F, H07VVH6-F
| No. x Sq mm | Outer Dimensions mm x mm | Max. Resistance at 20°C ohm/km | Current Capacity at 40°C amps |
|---|---|---|---|
| 4G x 1.0 | 15.0 x 4.6 | 18.1 | 11 |
| 4G x 1.5 | 16.4 x 5.0 | 12.1 | 14 |
| 4G x 2.5 | 19.4 x 6.0 | 7.41 | 18 |
| 4G x 4 | 22.7 x 6.7 | 4.95 | 26 |
| 4G x 6 | 25.6 x 7.7 | 3.3 | 31 |
| 4G x 10 | 32.2 x 9.4 | 19.1 | 42 |
| 4G x 16 | 37.7 x 10.8 | 1.21 | 57 |
| 4G x 25 | 46.0 x 13.1 | 0.78 | 72 |
| 4G x 35 | 51.0 x 14.4 | 0.554 | 90 |
Note: Insulation thickness, Sheath thickness and overall dimensions are nominal values. The number of wires is approximate and strand diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance as per IS 8130/1984, BS-6360, IEC-60228 & VDE-0295.








Conductor: The conductor we manufacture ensures safe and efficient electricity transmission with high performance and reliability, using high purity electrolytic grade bright annealed flexible bunched bare copper conductor as per ASTM B172.
Insulation: The insulation we provide acts as an effective barrier to prevent interference, energy loss, and short circuits. It is made from specially developed dielectric grade moisture-resistant PVC.
Sheath: The sheath offers excellent protection to keep the cable reliable and safe under demanding environmental conditions. It is made of high abrasion-resistant, tough, and flexible PVC.
| Core | North American Markets |
|---|---|
| 3 core | Red, Yellow, Black |
| 4 core | Green, Red, Yellow, Black |
| Sheath | Choice of Black or Blue |
![]() | |
![]() |
Reference Standard: UL 83
Working Voltage: 600 to 1000 V
Test Voltage: 3000 V
Temperature: 15°C to 75°C
Cable Nomenclature: A07VVH6-F, H07VVH6-F
| AWG/No. | Nominal Cable Dimensions inch x inch | Max. Resistance at 20°C ohm/1000 feet | Current Capacity at 30°C amps |
|---|---|---|---|
| 14/2 | 0.370 x 0.232 | 2.525 | 20 |
| 12/2 | 0.433 x 0.264 | 1.628 | 25 |
| 10/2 | 0.488 x 0.295 | 0.998 | 35 |
| 14/3 | 0.512 x 0.232 | 2.525 | 20 |
| 12/3 | 0.606 x 0.264 | 1.628 | 25 |
| 10/3 | 0.689 x 0.295 | 0.998 | 35 |
| 8/3 | 0.878 x 0.366 | 0.6282 | 50 |
| 6/3 | 1.035 x 0.425 | 0.3951 | 65 |
| 4/3 | 1.268 x 0.516 | 0.2485 | 85 |
| 2/3 | 1.437 x 0.579 | 0.1563 | 115 |
| 1/0-3 | 1.752 x 0.701 | 0.098 | 150 |
| 2/0-3 | 2.008 x 0.768 | 0.0729 | 175 |
| 3/0-3 | 2.315 x 0.886 | 0.0618 | 200 |
| No. x AWG | Outer Dimensions mm x mm | Max. Resistance at 20°C ohm/1000 feet | Current Capacity at 30°C amps |
|---|---|---|---|
| 14/2 W/14 Gr. | 0.512 x 0.232 | 2.525 | 20 |
| 12/2 W/12 Gr. | 0.606 x 0.264 | 1.628 | 25 |
| 10/2 W/10 Gr. | 0.689 x 0.295 | 0.998 | 35 |
| 8/2 W/10 Gr. | 0.819 x 0.366 | 0.6282 | 50 |
| 14/3 W/14 Gr. | 0.650 x 0.232 | 2.525 | 20 |
| 12/3 W/12 Gr. | 0.776 x 0.264 | 1.628 | 25 |
| 10/3 W/10 Gr. | 0.894 x 0.295 | 0.998 | 35 |
| 8/3 W/10 Gr. | 1.075 x 0.366 | 0.6282 | 50 |
| 6/3 W/10 Gr. | 1.295 x 0.433 | 0.3951 | 65 |
| 4/3 W/8 Gr. | 1.535 x 0.520 | 0.2485 | 85 |
| 2/3 W/8 Gr. | 1.713 x 0.579 | 0.1563 | 115 |
| 1/0-3 W/6 Gr. | 2.185 x 0.748 | 0.098 | 150 |
| 2/0-3 W/6 Gr. | 2.433 x 0.827 | 0.0729 | 175 |
| 3/0-3 W/6 Gr. | 2.559 x 0.882 | 0.0618 | 200 |
Note: Insulation thickness, Sheath thickness and overall dimensions are nominal values. The number of wires is approximate and strand diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance as per IS 8130/1984, BS-6360, IEC-60228 & VDE-0295.

Conductor: The conductor we manufacture ensures safe and efficient electricity transmission with high performance and reliability, using high purity electrolytic grade bright annealed flexible bunched bare copper conductor as per ASTM B172.
Insulation: The insulation we provide acts as an effective barrier to prevent interference, energy loss, and short circuits. It is made from specially developed dielectric grade moisture-resistant PVC.
Sheath: The sheath offers excellent protection to keep the cable reliable and safe under demanding environmental conditions. It is made of high abrasion-resistant, tough, and flexible PVC.
| Core | North American Markets |
|---|---|
| 3 core | Red, Yellow, Black |
| 4 core | Green, Red, Yellow, Black |
| Sheath | Choice of Black or Blue |
![]() | |
![]() |
Reference Standard: UL 83
Working Voltage: 600 to 1000 V
Test Voltage: 3000 V
Temperature: 15°C to 75°C
Cable Nomenclature: A07VVH6-F, H07VVH6-F
| AWG/No. | Nominal Cable Dimensions inch x inch | Max. Resistance at 20°C ohm/1000 feet | Current Capacity at 30°C amps |
|---|---|---|---|
| 14/2 | 0.370 x 0.232 | 2.525 | 20 |
| 12/2 | 0.433 x 0.264 | 1.628 | 25 |
| 10/2 | 0.488 x 0.295 | 0.998 | 35 |
| 14/3 | 0.512 x 0.232 | 2.525 | 20 |
| 12/3 | 0.606 x 0.264 | 1.628 | 25 |
| 10/3 | 0.689 x 0.295 | 0.998 | 35 |
| 8/3 | 0.878 x 0.366 | 0.6282 | 50 |
| 6/3 | 1.035 x 0.425 | 0.3951 | 65 |
| 4/3 | 1.268 x 0.516 | 0.2485 | 85 |
| 2/3 | 1.437 x 0.579 | 0.1563 | 115 |
| 1/0-3 | 1.752 x 0.701 | 0.098 | 150 |
| 2/0-3 | 2.008 x 0.768 | 0.0729 | 175 |
| 3/0-3 | 2.315 x 0.886 | 0.0618 | 200 |
| No. x AWG | Outer Dimensions mm x mm | Max. Resistance at 20°C ohm/1000 feet | Current Capacity at 30°C amps |
|---|---|---|---|
| 14/2 W/14 Gr. | 0.512 x 0.232 | 2.525 | 20 |
| 12/2 W/12 Gr. | 0.606 x 0.264 | 1.628 | 25 |
| 10/2 W/10 Gr. | 0.689 x 0.295 | 0.998 | 35 |
| 8/2 W/10 Gr. | 0.819 x 0.366 | 0.6282 | 50 |
| 14/3 W/14 Gr. | 0.650 x 0.232 | 2.525 | 20 |
| 12/3 W/12 Gr. | 0.776 x 0.264 | 1.628 | 25 |
| 10/3 W/10 Gr. | 0.894 x 0.295 | 0.998 | 35 |
| 8/3 W/10 Gr. | 1.075 x 0.366 | 0.6282 | 50 |
| 6/3 W/10 Gr. | 1.295 x 0.433 | 0.3951 | 65 |
| 4/3 W/8 Gr. | 1.535 x 0.520 | 0.2485 | 85 |
| 2/3 W/8 Gr. | 1.713 x 0.579 | 0.1563 | 115 |
| 1/0-3 W/6 Gr. | 2.185 x 0.748 | 0.098 | 150 |
| 2/0-3 W/6 Gr. | 2.433 x 0.827 | 0.0729 | 175 |
| 3/0-3 W/6 Gr. | 2.559 x 0.882 | 0.0618 | 200 |
Note: Insulation thickness, Sheath thickness and overall dimensions are nominal values. The number of wires is approximate and strand diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance as per IS 8130/1984, BS-6360, IEC-60228 & VDE-0295.